P192V

$275.00$375.00

The P192V is a venturi vacuum pump with two integral two-way solenoid control valves. The first valve controls the compressed air supply to the venturi and the second valve provides line pressure blow- off for fast part release and accurate part placement. There are 6 models available for both high and medium vacuum levels for handling porous and non- porous products efficiently. The pump is available with two additional vacuum ports that may be used for a gauge, switch or for an external blow off. Available options include a vacuum gauge, VG40 and vacuum switch models, AP10 and AP30P19.

 

How To Order

1. Review model options from performance specification in the Select Model tab below
2. Select the desired “model” from drop down list
3. Select options if applicable. (Price and photo will update when applicable)
4. Select “quantity” from drop down list
5. Select “add to cart”
6. Complete your purchase

Clear
SKU: N/A Categories: ,

Use the table below to choose a model based on your application, then fill out the form above to purchase.

H Series: Ideal for handling non-porous objects such as steel, glass and laminate and for evacuating vessels to high vacuum levels.

Model #Air Consumption
SCFM (l/min)
Vacuum Flow - SCFM (l/min) vs. Vacuum Level - % Vacuum
0%10%20%30%40%50%60%70%80%90%93%
P192V-4.5-1.8H3.8 (107.6)4.2 (118.9)3.65 (103.4)3.25 (92.0)3 (85.0)2.8 (79.3)2.4 (68.0)1.9 (53.8)1.6 (45.3)0.95 (26.9)0.45 (12.7)0
P192V-5-2.2H7.8 (220.9)5.4 (152.9)4.7 (133.1)3.85 (109)3.3 (93.4)3 (85)2.6 (73.6)2.1 (59.5)1.6 (45.3)1.2 (34)0.6 (17)0
Model #Air Consumption
SCFM (l/min)
Evacuation Time in Seconds based on 1 Cubic Foot Volume (1 Liter Volume) vs % Vacuum
0%10%20%30%40%50%60%70%80%90%93%
P192V-4.5-1.8H01.3(0.05)2.8 (0.10)4.8 (0.21)7.6(0.13)11.0(0.40)15.5(0.55)21.7 (0.76)32.0 (1.13)68.9 (2.43)108.0 (3.81)
P192V-5-2.2H01.2 (0)2.1 (0.1)3.4 (0.1)5.2 (0.2)7.7 (0.3)11.5 (0.4)20 (0.7)28.0(1.0)62.6 (2.2)98.1 (3.5)

M Series: Ideal for handling porous objects such as corrugated, wood and flexible packaging and for evacuating vessels to medium vacuum levels.

Model #Air Consumption
SCFM (l/min)
Vacuum Flow - SCFM (l/min) vs. Vacuum Level - % Vacuum
0%10%20%30%40%50%60%70%
P192V-4.5-1.6M3.8 (107.6)5 (141.6)4.6 (130.3)4.05 (114.7)3.5 (99.1)2.75 (77.9)1.8 (51.0)0.9 (25.5)0
P192V-5-1.8M4.8 (135.9)6 (169.9)5.3 (150.1)4.9 (138.8)4 (113.3)3.5 (99.1)2.5 (70.8)1.1 (31.1)0
P192V-6-2.2M7.8 (220.9)9.5 (269.0)9.2 (260.5)8.3 (235.0)7 (198.2)4.7 (133.1)3.4 (96.3)2.2 (62.3)0
Model #Air Consumption
SCFM (l/min)
Evacuation Time in Seconds based on 1 Cubic Foot Volume (1 Liter Volume) vs % Vacuum
0%10%20%30%40%50%60%70%
P192V-4.5-1.6M01.0 (.04)2.23 (0.08)3.86 (.14)6.49 (0.2)10.68 (0.4)19.49 (0.7)51.0 (1.8)
P192V-5-1.8M00.75 (0.0)1.9 (0.1)3.2 (0.1)5.3 (0.2)8.7 (0.3)17.1 (0.6)42.6 (1.5)
P192V-6-2.2M00.45 (0.0)1.1 (0.0)2.4 (0.1)3.8 (0.1)6.0 (0.2)9.7 (0.3)15.4 (0.5)

* Evacuation speed is linear with volume, i.e. a 2 cu. ft. volume will take twice as long as 1 cu. ft. volume to evacuate to a given vacuum level.
** Values are based on an operating pressure of 80 PSI (5.5 bar)